ENERGYLOGIC HEATING SYSTEMS:

USED-OIL FURNACES AND BOILERS
System Features:

Patented Fuel Metering Pump:
Patented SteadyFlo pump system automatically provides accurate and precise metering over a wide range of fuels eliminating the need for manual flame adjustments regardless of viscosity.

Commonly Used Fuels:
Burns used Crankcase oils, ATF, Hydraulic oils, No. 2 fuel oil, Transmission oil - up to 90W.

Integrated Air Compressor:
On-board compressor eliminates the need to connect to shop air.

Beckett Burner:
Beckett burners, long recognized as industry-best.

Patented Flame Retention Head:
In conjunction with the Patented Nozzle Block Assembly ensures a controlled flame and optimal combustion.

Stainless Steel Heat Exchanger (Furnaces):
Because it is made of 18SR stainless designed to withstand high temperatures and resist corrosion, the heat exchanger is warranted for ten years. This design also eliminates the need for target walls and tubes.

Wet Floor Based Heat Exchanger (Boilers):
Water-cooling of heat exchanger prevents hot spots and metal deterioration.

Squirrel Cage Blower (Furnaces):
Permits quieter operation, increases efficiency and allows ducting when required.

Barometric Damper and Draft Gauge (Furnaces):
Increases furnace efficiency.

Hourmeter:
Analog meter records the actual burn time, not the blower time, so periodic maintenance is completed only when necessary.

Easy-clean Design:
Features such as the swing-away burner, horizontal heat exchanger (furnaces only) and access cap (furnaces) and removable rear access panel (boilers) make cleaning the heat exchanger and components quick and easy.

UL and ASME Certifications:
The entire EnergyLogic systems including tank, furnace or boiler, components, wiring and plumbing are UL certified for peace of mind. EnergyLogic boilers are ASME certified vessel construction, made of heavy carbon-steel for more strength, less corrosion and longer expected life than cast-iron boilers.


Energy Logic Boiler Specifications:
  EL-200 B EL-375 B EL-500 B
Fuel Flow Rate 1.4 gal. per hour 2.7 gal. per hour 3.6 gal. per hour
BTU Input 200,000 BTU 375,000 BTU 499,000 BTU
Max. Water Output Temperature 230° F 230° F 230° F
Domestic Hot Water Output 4.0 gal. per minute at 100° F 6.0 gal. per minute at 100° F 8.0 gal. per minute at 100° F
Boiler Capacity 30 gal. 43 gal. 52 gal.
Fuel Tank (standard) Single-wall, 250 gal. Workbench type Single-wall, 250 gal. Workbench type Single-wall, 250 gal. Workbench type
System Dimensions
(without tank)
45"h x 32"w x 50d 50"h x 28"w x 54d 45"h x 32"w x 68d
Tank Dimensions
(with pump)
37.5"h x 32"w x 69"l 37.5"h x 32"w x 69"l 37.5"h x 32"w x 69"l
Exhaust Fuel Diameter 8" 8" 8"
Electrical Requirements 115 VAC 60Hz, 20 amp dedicated circuit 115 VAC 60Hz, 20 amp dedicated circuit 115 VAC 60Hz, 20 amp dedicated circuit
Shipping Weight
(without Tank)
812lbs. 1,025 lbs. 1,125 lbs.
Shipping Weight
(with std. Tank)
1,237 lbs. 1,450 lbs. 1,550 lbs.


EnergyLogic Furnace Specifications:
  EL-140 H EL-200 H EL-340 H
Fuel Flow Rate 1.0 gal. per hour 1.4 gal. per hour 2.25 gal. per hour
BTU Input 142,000 BTU 200,000 BTU 340,000 BTU
Warm Air Temp. Rise 100-120° F 100-120° F 100-120° F
Air Flow 1,000 cfm 1,500 cfm 2800 cfm
Fuel Tank (standard) Single-wall, 250 gal. Single-wall, 250 gal. Single-wall, 250 gal
Furnace Dimensions 18"h x 18"w x 92"l 18"h x 18"w x 105"l 28"h x 22"w x 99"l
Tank Dimensions (with pump) 37.5"h x 32"w x 69"l 37.5"h x 32"w x 69"l 37.5"h x 32"w x 69"l
Exhaust Fuel Diameter 8" 8" 8"
Electrical Requirements 115 VAC 60Hz, 25 amp dedicated circuit 115 VAC 60Hz, 25 amp dedicated circuit 115 VAC 60Hz, 25 amp dedicated circuit
Shipping Weight
(without Tank)
375 lbs. 395 lbs. 545 lbs.
Shipping Weight
(with std. Tank)
730 lbs. 750 lbs. 895 lbs.